Gas detector for ammonia (NH3) EVIKON E2638-NH3-E-R-B-LED-230, warning signal: visual (flashing display) + audible, power supply: 230 VAC, electrochemical sensor, measuring range: 0–300 ppm. More information
Out of stock - can be requested
| Detector type | Stationary |
| Output signal | ModBus RS485, 2x Switching Relay, 2x Analog Output 4-20mA/0-10V |
| Power Supply | 230 VAC |
| Type of gas | NH3 - Ammonia |
| Weight | 0.50 kg |
Declaration of conformity download
Download PDFCatalog sheet download
Download PDFData sheet download
Download PDFThe gas concentration detection sensor (gas detector) is used to detect and provide early warning of a dangerous (explosive or toxic) concentration of the monitored gas. The sensor is suitable for use in industrial premises, refrigeration equipment or warehouses, and other enclosed spaces where hazardous quantities of gas may accumulate. Conversely, this detector is not suitable for use in places where higher concentrations of ammonia are present over long periods, such as poultry houses and cattle or pig farms.
The detector is equipped with two-stage signalling – visual (LED indication) and audible (85 dB). Two output relays (volt-free) with switching contacts can be used for remote signalling or control of ventilation / solenoid valve, etc. The sensor is built on the unified PluraSens platform. In addition to the switching relays, the platform also enables the detector to be connected via two analogue outputs 0-10V / 4-20mA and a ModBus RS485 digital interface.
Manufactured in a robust design with IP65 protection - ABS plastic, resistant to mechanical damage. Rigid, tough, resistant to both low and high temperatures, low absorbency, and safe for health.
The sensor service life is more than 10 years.
When ordering, it is necessary to specify the application in order to select the correct sensor type. The recommended coverage area for one sensor is 80-120 m2, radius 5-6 m.
Each sensor is factory calibrated to default values. The law stipulates that recalibration must be carried out at least once every 12 months. Calibration may only be carried out by a person certified by the manufacturer.
For more information about calibration - www.kalibrovat. cz
The sensor is intended for the detection of flammable gases:
Ammonia (NH3)
DETECTOR CALIBRATED FOR AMMONIA.
Tip: Get automatic reminders of the statutory calibration date via the www.kalibrovat.cz service
Tip: The detector can be equipped with a remote wired sensor.
We respond to your product queries as quickly as possible, usually within 24 hours.