Questions? +32 460 226 991 (English). EU-wide delivery!

ENBRA SHARKY 774 Heat Meter DN 15, 1.5 m3/h, M-Bus (K3113799)

ENBRA SHARKY 774 Heat Meter DN 15, 1.5 m3/h, M-Bus (K3113799)

ENBRA
  • Product code: K3113799
  • Manufacturer code: K3113799
  • Warranty: 2 years

Ultrasonic heat meter SHARKY 774 compact DN15, qp 1.5 m³/h, with M-Bus interface. For billing heat measurement in apartment buildings and transfer stations. MID class 2 approved. More information

  • Availability

    Do týdne

  • Out of stock  
List price € 450,37
Price excluding VAT € 308,93
Price with VAT 21 % € 373,81
+

Parameters and catalogs

Connection size DN 15
Connection Type External thread
Flow 1.5 m3/h
M-BUS communication Yes
Medium Water
Medium Temperature 15...90°C
Pressure PN 16
Type of Meter Ultrasonic
Weight 1.25 kg

Catalog sheet download

Download PDF

Technical data sheet EN download

Download PDF

SHARKY 774 compact is a compact ultrasonic heat meter from the German manufacturer Diehl Metering. It is designed for billing measurement of thermal energy consumption in both heating and cooling systems. This version has a nominal flow rate qp of 1.5 m³/h, nominal size DN15 (G¾B), and an M-Bus communication interface for remote data reading.

Where the product is used

The meter is intended for billing heat measurement in apartment buildings, apartment substations, heating circuits with heat pumps, and cooling systems. Thanks to its height of just 54 mm above the pipe centreline, it also fits into compact heat interface units and narrow installation shafts where a mechanical meter may not have sufficient space.

It is suitable for property managers, HVAC designers, and plumbing companies that require a certified meter for allocating heating costs among end users.

SHARKY 774 compact in an apartment substation
Ultrasonic measurement

Measuring principle

Ultrasonic technology with no moving parts

No wear, low pressure loss

1:100

dynamic range qp/qi

Long battery life

Service life

Operation on a single battery set

For M-Bus operation, 2× AA batteries

12

years of battery life

Resistance to interference

Resistance

Stable measurement even with PWM pumps

MID electromagnetic immunity

E2 + M2

immunity class

Principle of ultrasonic flow measurement

Ultrasonic flow measurement

The meter evaluates flow using the ultrasonic transit-time method. There are no moving parts inside the pipe, which eliminates mechanical wear and allows the meter to maintain its accuracy throughout its service life. The low starting flow rate (2.5 l/h for qp 1.5 m³/h) ensures that the meter also captures very small consumptions.

Ultrasonic measurement is insensitive to suspended particles in the heating water, which means the device performs well even in systems where mechanical meters tend to become clogged.

M-Bus communication for remote reading

The meter is equipped with an M-Bus interface in accordance with EN 13757-3. Data is transmitted over two non-polarised wires, the interface is galvanically isolated, and it supports automatic baud rate detection at 300 and 2,400 baud. The configurable telegram allows reading of current energy, power, volume, flow rate, temperatures, and historical data.

Current consumption is recalculated every 2 seconds, while temperatures are updated every 16 seconds, so the user always sees the current system status in the central system.

Technical parameters:

  • Nominal flow rate qp: 1.5 m³/h
  • Nominal size DN: 15
  • Connection thread: G¾B (R½ union fitting)
  • Installation length: 110 mm (190 mm with union fitting)
  • Minimum flow rate qi: 15 l/h
  • Maximum flow rate qs: 3 m³/h
  • Starting flow rate: 2.5 l/h
  • Pressure loss at qp: 120 mbar
  • Temperature range for heating: 5–105 °C / 5–130 °C (depending on version)
  • Min. temperature difference ΔΘmin: 3 K
  • Calculator protection rating: IP65
  • Flow sensor protection rating: IP54
  • Communication: M-Bus
    • 2 wires, non-polarised, galvanically isolated
    • Auto baud 300 / 2,400
    • Protocol according to EN 13757-3
  • Temperature sensors: Pt 500, two-wire, Ø 5.2 mm, cable 1.45 m / 1.95 m
  • Measuring cycle: flow 2 s / temperature 16 s
  • Power supply: 2× AA batteries, 3.6 V DC, battery life up to 12 years
  • Operating ambient temperature: 5–55 °C
  • Certification: MID DE-13-MI004-PTB008, class 2, PTB K7.2 (cooling)
  • Immunity class: E2 (electromagnetic) + M2 (mechanical)

Frequently asked questions

An ultrasonic meter has no moving parts, so it does not suffer from mechanical wear in operation and maintains its accuracy throughout its service life. It achieves lower pressure loss, has a wider dynamic range (qp/qi up to 1:100), and can detect even very low flow rates from 2.5 l/h. At the same time, it is insensitive to dirt and suspended particles in the heating water, to which mechanical meters are prone.

M-Bus (Meter-Bus) is a standardised bus for remote meter reading in accordance with EN 13757-3. The meter is connected via a two-wire non-polarised line to an M-Bus master (converter or concentrator), which collects the data and passes it on to a higher-level system. Communication is galvanically isolated and supports automatic speed detection at 300 and 2,400 baud. In addition to M-Bus, a ZVEI optical interface is also available for local service reading.

The meter can be installed in any position – horizontally, vertically on a riser or downpipe, or even inverted above the pipe centreline. This orientation independence is due to the ultrasonic measuring principle, which does not require straight pipe lengths upstream and downstream of the meter to the same extent as mechanical water meters.

For the M-Bus version, the battery lasts up to 12 years under standard operating conditions. Higher ambient temperatures shorten battery life, which is why operation below 35 °C is recommended. The battery cannot be replaced by the user during operation; replacement is carried out by the manufacturer's service laboratory.

Yes. The SHARKY 774 compact is approved in accordance with the MID directive (DE-13-MI004-PTB008) in accuracy class 2 and for cooling according to PTB K7.2. It therefore meets the requirements for a legally controlled meter used for billing heat and cooling. The meter belongs to environmental class E2 (electromagnetic immunity) and M2 (mechanical immunity), making it less susceptible to interference from PWM circulation pumps and similar sources.

We respond to your product queries as quickly as possible, usually within 24 hours.

Nenašli jste to, co jste chtěli vědět?