Ultrasonic heat meter SHARKY 774 compact DN15, qp 1.5 m³/h, with M-Bus interface. For billing heat measurement in apartment buildings and transfer stations. MID class 2 approved. More information
Do týdne
| Connection size | DN 15 |
| Connection Type | External thread |
| Flow | 1.5 m3/h |
| M-BUS communication | Yes |
| Medium | Water |
| Medium Temperature | 15...90°C |
| Pressure | PN 16 |
| Type of Meter | Ultrasonic |
| Weight | 1.25 kg |
Catalog sheet download
Download PDFTechnical data sheet EN download
Download PDFSHARKY 774 compact is a compact ultrasonic heat meter from the German manufacturer Diehl Metering. It is designed for billing measurement of thermal energy consumption in both heating and cooling systems. This version has a nominal flow rate qp of 1.5 m³/h, nominal size DN15 (G¾B), and an M-Bus communication interface for remote data reading.
The meter is intended for billing heat measurement in apartment buildings, apartment substations, heating circuits with heat pumps, and cooling systems. Thanks to its height of just 54 mm above the pipe centreline, it also fits into compact heat interface units and narrow installation shafts where a mechanical meter may not have sufficient space.
It is suitable for property managers, HVAC designers, and plumbing companies that require a certified meter for allocating heating costs among end users.

Measuring principle
No wear, low pressure loss
1:100
dynamic range qp/qi
Service life
For M-Bus operation, 2× AA batteries
12
years of battery life
Resistance
MID electromagnetic immunity
E2 + M2
immunity class

The meter evaluates flow using the ultrasonic transit-time method. There are no moving parts inside the pipe, which eliminates mechanical wear and allows the meter to maintain its accuracy throughout its service life. The low starting flow rate (2.5 l/h for qp 1.5 m³/h) ensures that the meter also captures very small consumptions.
Ultrasonic measurement is insensitive to suspended particles in the heating water, which means the device performs well even in systems where mechanical meters tend to become clogged.
The meter is equipped with an M-Bus interface in accordance with EN 13757-3. Data is transmitted over two non-polarised wires, the interface is galvanically isolated, and it supports automatic baud rate detection at 300 and 2,400 baud. The configurable telegram allows reading of current energy, power, volume, flow rate, temperatures, and historical data.
Current consumption is recalculated every 2 seconds, while temperatures are updated every 16 seconds, so the user always sees the current system status in the central system.
Technical parameters:
An ultrasonic meter has no moving parts, so it does not suffer from mechanical wear in operation and maintains its accuracy throughout its service life. It achieves lower pressure loss, has a wider dynamic range (qp/qi up to 1:100), and can detect even very low flow rates from 2.5 l/h. At the same time, it is insensitive to dirt and suspended particles in the heating water, to which mechanical meters are prone.
M-Bus (Meter-Bus) is a standardised bus for remote meter reading in accordance with EN 13757-3. The meter is connected via a two-wire non-polarised line to an M-Bus master (converter or concentrator), which collects the data and passes it on to a higher-level system. Communication is galvanically isolated and supports automatic speed detection at 300 and 2,400 baud. In addition to M-Bus, a ZVEI optical interface is also available for local service reading.
The meter can be installed in any position – horizontally, vertically on a riser or downpipe, or even inverted above the pipe centreline. This orientation independence is due to the ultrasonic measuring principle, which does not require straight pipe lengths upstream and downstream of the meter to the same extent as mechanical water meters.
For the M-Bus version, the battery lasts up to 12 years under standard operating conditions. Higher ambient temperatures shorten battery life, which is why operation below 35 °C is recommended. The battery cannot be replaced by the user during operation; replacement is carried out by the manufacturer's service laboratory.
Yes. The SHARKY 774 compact is approved in accordance with the MID directive (DE-13-MI004-PTB008) in accuracy class 2 and for cooling according to PTB K7.2. It therefore meets the requirements for a legally controlled meter used for billing heat and cooling. The meter belongs to environmental class E2 (electromagnetic immunity) and M2 (mechanical immunity), making it less susceptible to interference from PWM circulation pumps and similar sources.
We respond to your product queries as quickly as possible, usually within 24 hours.