The EVIKON E2608-CO2 detector for carbon dioxide detection is equipped with two-stage signalling with switching relay outputs. It does not have its own visual or audible alarm. The E2608 series detectors are an intelligent solution for modern applications, featuring ModBus RS485 communication and two analogue 4-20 mA/0-10 V outputs. More information
Delivery to Belgium (days are avarages)
DHL Express: 1.2 workdays, € 16,94
| Detector type | Stationary |
| Output signal | ModBus RS485, 2x Switching Relay, 2x Analog Output 4-20mA/0-10V |
| Power Supply | 230 VAC |
| Type of gas | CO2 - Carbon dioxide |
| Weight | 0.35 kg |
Datasheet download
Download PDFAssembly instructions download
Download PDFDeclaration of conformity download
Download PDFThe carbon dioxide detection sensor is used for detecting and providing early warning of dangerous (toxic) concentrations of carbon dioxide. Typical applications include HVAC and air quality control in public spaces, offices, greenhouses, underground car parks or boiler rooms, and other places where toxic amounts of carbon dioxide could accumulate. For accurate detection, the device uses a calibrated and temperature-compensated NDIR optical sensor. This sensor ensures high stability, repeatability, and a long detector service life. In the event of a leak, carbon dioxide can also accumulate in enclosed spaces up to a toxic level. It is therefore necessary to ensure timely leak warning by means of a detector.
Carbon dioxide is heavier lighter than air. The detector should be installed just above floor level, away from corners, recesses, or holes. The recommended coverage area for one detector is 500...1000m2, corresponding to a radius of approx. 12...18m.
The EVIKON E2608-CO2 detector is equipped with two-stage signalling with outputs to switching relays. It does not have its own visual or audible signalling. Detectors from the E2608 series are an intelligent solution for modern applications with ModBus RS485 communication and two analogue outputs 4-20mA/0-10V.
| Measured gas | Alarm 1 - Relay 1 | Alarm 2 - Relay 2 |
| CO2 | 2500ppm CO2 | 5000ppm CO2 |
The sensor can be ordered in the following versions:
Manufactured in a robust design with IP65 protection - ABS plastic, resistant to mechanical damage. Rigid, tough, resistant to both low and high temperatures, low absorbency, and safe for health.
The sensor service life is more than 15 years.
Each sensor is factory-calibrated to default values (described in the manual). The law stipulates that recalibration must be carried out at least once every 12 months. Calibration may only be performed by a person certified by the manufacturer.
Do not hesitate to contact us for recalibration!
Tip: Get automatic reminders of the statutory calibration date via the www.kalibrovat.cz service
We respond to your product queries as quickly as possible, usually within 24 hours.