Questions? +32 460 226 991 (English). EU-wide delivery!

Gas Detector for Methane EVIKON E2670-LEL(CH4)-R

Gas Detector for Methane EVIKON E2670-LEL(CH4)-R

EVIKON
  • Product code: E2670-LEL(CH4)-R-2
  • Manufacturer code: E2670-LEL(CH4)-R-2
  • Warranty: 2 years

Methane detector Evikon E2670-R-LEL with MOS sensor, digital ModBus RS485 communication, two analogue outputs, and two relays. IP65 protection, 24 V DC power supply, suitable for ATEX zones 2 and 22. More information

  • Delivery

    Delivery to Belgium (days are avarages)

    FedEx:
    2.7 workdays € 0,00
    FedEx Priority:
    1.7 workdays € 12,71
    DHL Express:
    1.2 workdays € 16,94

    DHL Express: 1.2 workdays, € 16,94

  • In stock 3 pcs  
     
Price excluding VAT € 706,00
Price with VAT 21 % € 854,26
+

Parameters and catalogs

Atex Zone 22, Zone 2
Output signal ModBus RS485, 2x Analog Output 4-20mA/0-10V, 2 x switching relay
Power Supply 24 VDC
Type of gas CH4-Methane
Weight 1.35 kg

Data sheet eng download

Download PDF

Staircase statement download

Download PDF

Methane Detector is used for measuring the values of detected gas in the air and providing timely warnings against dangerous concentrations.

It does not have its own light and sound signals. The E2670 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two analogue outputs 4-20mA/0-10V. They are also equipped with two switching relays that activate connected devices upon recording two pre-set values.

Manufactured in robust aluminium design with IP65 protection, resistant to mechanical damage. Suitable for use in ATEX zones 2 and 22. More details about ATEX in the declaration of conformity and technical sheet.

Each detector is factory-calibrated to default values (described in the manual). According to user needs, the detector can be set to a measuring range of 0...100% LEL. The law states that recalibration must be carried out at least once every 12 months. Calibration can only be performed by a person certified by the manufacturer.

The recommended coverage area for one sensor is 80-120 m2, 5-6 m radius.

For recalibration, do not hesitate to contact us!

The detector is designed to detect:
Acetylene / Butane / Propane / Hydrogen / Methane
Factory calibrated for Methane (For setting to another gas, provide information in the order note)

Features:

  • Sensitive and stable detection
  • Long lifespan of MOS sensor (>5 years)
  • Wall mounting, IP65 protection
  • ATEX zones 2, 22
  • Two analogue outputs 4-20mA/0-10V
  • Digital communication ModBus RS485
  • 2 × switching relays

Tip: Get automatically notified about the legal calibration date with the service www.kalibrovat.cz

We respond to your product queries as quickly as possible, usually within 24 hours.

Nenašli jste to, co jste chtěli vědět?