Questions? +32 460 226 991 (English). EU-wide delivery!

Pressure Sensor Huba Control 528 0-16 Bar Ex1 (528.9310041511)

Pressure Sensor Huba Control 528 0-16 Bar Ex1 (528.9310041511)

HUBA CONTROL
  • Product code: 528.9310041511
  • Manufacturer code: 528.9310041511
  • Warranty: 2 years

Compact pressure sensor Huba Control type 528 for measuring the relative pressure of liquids and gases. Suitable for industrial applications, stainless steel design, and 4–20 mA output. Contact us for bulk orders. More information

  • Availability

    Out of stock - can be requested

  • Out of stock  
Price excluding VAT € 379,44
Price with VAT 21 % € 459,12
+

Parameters and catalogs

Atex Zone 1
IP Rating IP 65
Output signal 4-20 mA
Power Supply 24 VDC
Pressure range 0...16 bar
Weight 0.09 kg

Data sheet - ENG download

Download PDF

The pressure sensor Huba Control 528 uses proven ceramic technology, ensuring long-term stability and high measurement accuracy. It is suitable for a wide range of industrial applications with liquids and gases, where reliability and compact design are required.

Thanks to its robust stainless steel construction and design with a DIN EN 175301-803-A connector, the sensor offers easy installation and durability even in demanding operating conditions. The variant with 4–20 mA output (10–30 VDC, Ex-protected) is designed for safe measurement in environments requiring intrinsic safety.

Main Features

  • Compact and durable stainless steel construction (1.4404 / AISI 316L)
  • High accuracy and minimal temperature influence
  • 4–20 mA output, 10–30 VDC power supply
  • Explosion protection Ex ia IIC T4 Ga/Gb
  • DIN EN 175301-803-A connection

Technical Specifications

Pressure Range (relative) 0–16 bar
Output / Power Supply 4–20 mA / 10–30 VDC (Ex version)
Electrical Connection DIN EN 175301-803-A
Pressure Connection G ¼ sealed from the back and manometric with profile sealing ring (FPM)
Sealing Material FPM (fluoroelastomer)
Material Stainless steel 1.4404 / AISI 316L
Protection Class IP65
Medium Temperature Range -15...125 °C
Certification ATEX, CE, IECEx

Notes:
Relative pressure measurement means that the pressure is measured against the ambient pressure, not against absolute zero (vacuum).
FPM is suitable for temperatures -15...+120 °C.
The sealing can be chosen in the following variants: FPM (–15...+120 °C), EPDM (–30...+120 °C).
Parameter adjustments can be made and a more favourable price offered for orders over 5 pieces.

We respond to your product queries as quickly as possible, usually within 24 hours.

Nenašli jste to, co jste chtěli vědět?