Questions? +32 460 226 991 (English). EU-wide delivery!

Refrigerant Gas Detector EVIKON E2630-HFC-230 (R454C)

Refrigerant Gas Detector EVIKON E2630-HFC-230 (R454C)

EVIKON
  • Product code: E2630-HFC-230(R454C)
  • Manufacturer code: E2630-HFC-230(R454c)
  • Warranty: 2 years

Gas detector for R454C refrigerant EVIKON E2630-HFC, alarm signal: visual + audible, power supply: 90...265 VAC, measuring range: 0...500 ppm. More information

  • Delivery

    Delivery to Belgium (days are avarages)

    FedEx:
    2.7 workdays € 7,02
    Bpost HD (Home Delivery):
    4.4 workdays € 10,64
    BPost - PP (Pick-up Point):
    3.9 workdays € 9,91
    FedEx Priority:
    1.7 workdays € 12,71
    DHL Express:
    1.2 workdays € 16,94

    DHL Express: 1.2 workdays, € 16,94

  • In stock 3 pcs  
     
Price excluding VAT € 201,00
Price with VAT 21 % € 243,21
+

Parameters and catalogs

Detector type Stationary
Equipment Siren 85dB, LED
IP Rating IP 65
Output signal 2x SPDT relay
Power Supply 230 VAC
Type of gas Refrigerant - R454c
Weight 0.44 kg

Evikon E2630-HFC is a detector designed to monitor the concentration of R454C refrigerant in air. The device uses a semiconductor sensor that provides accurate real-time measurements. Thanks to its reliable performance and easy installation, it is an ideal choice for commercial and industrial applications where refrigerant leak monitoring is essential.

The device is housed in a wall-mounted enclosure with IP65 protection, ensuring resistance to dust and water. The E2630-HFC detector is equipped with a visual and audible alarm that provides timely warning when the R454C concentration rises. In addition, it offers two SPDT relay outputs for easy integration with ventilation control systems or alarms, ensuring a comprehensive safety solution.

Typical applications:

The E2630-HFC detector is intended for monitoring R454C refrigerant leaks in environments such as plant rooms, air conditioning and refrigeration equipment, refrigerant storage areas, or other installations where refrigerant concentration monitoring is required. The device provides early leak detection, helping to minimise the risks associated with refrigerant leakage and protect both the environment and equipment.

R454C:

R454C is a next-generation synthetic refrigerant used in air conditioning and refrigeration systems as a replacement for refrigerants with a higher global warming potential (GWP), such as R404A. It is a blend of hydrofluoroolefin (HFO) and hydrofluorocarbon (HFC), ensuring efficient heat transfer with a significantly lower climate impact. Unlike non-flammable refrigerants, R454C is classified as mildly flammable (ASHRAE A2L class), and therefore monitoring for leaks is crucial not only from an environmental perspective, but also for operational safety.


Calibration certificate

Calibration certificate

Every Evikon gas detector package includes a factory-issued calibration certificate. The calibration certificate is in English. Gas concentration measurement is affected by operating temperature and humidity, therefore the detector is calibrated during production with enhanced safety in mind.


Detector

Key features:

  • Detected substances: R454C refrigerant
  • May respond to: Other refrigerants R404a, R410a, R32, R-1234yf, R-1234ze, flammable gases, toluene, xylenes, vapours from cleaning agents, etc.
  • Sensor type: Metal oxide semiconductor sensor with diffusion sampling.
  • Measuring range: 0...500 ppm with 1 ppm resolution.
  • Two-stage detection
  • Response time: Less than 120 seconds with signal update every second.
  • Alarms: Flashing LED and siren (85 dB).
  • Recommended recalibration interval: 6–12 months
  • Expected sensor lifetime: > 5 years
  • Avoid strong mechanical shocks, vibrations, or electromagnetic interference (EMI). Also avoid exposure to corrosive gases or products containing silicone.

Factory settings:

  • Calibration gas: R454C refrigerant
  • Measuring range: 0...500 ppm
  • Alarm settings:
    • ALARM1 = 200 ppm
    • ALARM2 = 500 ppm
  • Automatic alarm reset after ventilation (can be switched to manual mode using a magnet)

Specifications:

  • Power supply: 230 VAC
  • Power consumption: < 2 VA
  • Max. load of SPDT relay outputs: 250 VAC / 30 VDC, 5 A max
  • Operating conditions: -40...+70 °C, <95% RH, pressure 0.9...1.1 atm
  • Enclosure dimensions: H140 × W145 × D55 mm
  • Protection class: IP65

This detector is suitable for monitoring R407c refrigerant in various environments, including industrial facilities and storage areas. It offers stable performance with low maintenance requirements, making it a practical solution for long-term use across a wide range of applications.


Register your detector

We will notify you when the statutory calibration date is due.

  • Notification 1 month before calibration expiry
  • By email
  • Free, hassle-free service

Order recalibration

Recalibration is required by law at least once a year.

  • Postal calibration within 72 hours
  • On-site calibration
  • Calibration certificate

We respond to your product queries as quickly as possible, usually within 24 hours.