Questions? +32 460 226 991 (English). EU-wide delivery!

Room Temperature Controller for Fan Coil Siemens RCC 10 (RCC10)

Room Temperature Controller for Fan Coil Siemens RCC 10 (RCC10)

SIEMENS
  • Product code: RCC10
  • EAN : 7612914000675
  • Manufacturer code: RCC10
  • Warranty: 2 years

Electronic room temperature controller for 2-pipe fan coil. Input for exhaust air sensor. More information

  • Delivery

    Delivery to Belgium (days are avarages)

    FedEx:
    2.7 workdays € 7,02
    Bpost HD (Home Delivery):
    4.4 workdays € 10,64
    BPost - PP (Pick-up Point):
    3.9 workdays € 9,91
    FedEx Priority:
    1.7 workdays € 12,71
    DHL Express:
    1.2 workdays € 16,94

    DHL Express: 1.2 workdays, € 16,94

  • More than 5 pcs in stock  
     
List price € 97,67
Price excluding VAT € 60,54
Price with VAT 21 % € 73,25
+

Parameters and catalogs

Control Control knob
Control Three-speed
Design Wired
External sensor Yes
Measurement accuracy 0.7 °C
Power Supply 230 VAC
Program No
Setting range 8...30 °C
Weight 0.25 kg

Datasheet download

Download PDF

Electronic Room Temperature Controller RCC 10 for 2-pipe fan-coil units. The controller is equipped with a rotary knob for setting the desired temperature, a switch, and status LED indicators.

Application

Control of room temperature in spaces heated or cooled by two-pipe fan-coil units.
Two-position valve control and operation of a 3-speed fan.

The controller is suitable for use in systems with automatic sequence switching between heating/cooling and in systems with continuous operation in heating or cooling sequences.

Functions

Using the built-in temperature sensor or via an additional temperature sensor (QAH 11.1), the controller obtains information about the current temperature and ensures temperature regulation to the desired value. Regulation is carried out by 2-position control of the actuator of the regulating valve (open/closed).

Operating Modes

Normal Mode - heating or cooling sequence with automatic switching and manually set fan speeds III, II, or I. In this mode, the controller responds to the set desired temperature value.

Frost Protection Mode - when the temperature drops below 8 °C, the controller opens the heating valve and the fan runs at the set speed.

Economy Mode - the heating value in economy mode is 16 °C and the cooling value is 28 °C.

Protection Against Increased Humidity