Questions? +32 460 226 991 (English). EU-wide delivery!

Smart Gas Detector for Ethylene with Wi-Fi Module EVIKON E2639-C2H4-1.5K-WF

  • 6 variant

Smart Gas Detector for Ethylene with Wi-Fi Module EVIKON E2639-C2H4-1.5K-WF

EVIKON
  • Product code: E2639-C2H4-1.5K-WF
  • Manufacturer code: E2639-C2H4-1.5K-WF
  • Warranty: 2 years

Smart ethylene (C2H4) detector EVIKON E2639 with a range of 0...1500 ppm. Robust IP65-rated enclosure, 3 relays, RS485 Modbus communication, Wi-Fi module, built-in LED and audible alarm. More information

  • Availability

    Out of stock - can be requested

  • Out of stock  
Price excluding VAT € 1 113,00
Price with VAT 21 % € 1 346,73

Parameters and catalogs

Detector type Stationary
Equipment Siren 85dB, LED
IP Rating IP 65
Output signal ModBus RS485, 3x SPDT relay, 2x Analogue output 4-20mA
Power Supply 14...36 VDC
Type of gas C2H4-Ethylene
Weight 0.50 kg

E2639-C2H4 is a detector designed for monitoring high concentrations of ethylene in ambient air. The device is equipped with a temperature-compensated sensor that ensures reliable detection and stable measurement, and is housed in a wall-mounted enclosure with IP65 protection. The E2639 features three SPDT relays with a maximum load of 250 VAC 5 A. Two relays are used for two-stage detection. The third relay indicates a sensor fault. Communication with higher-level systems is provided via the RS485 Modbus RTU digital interface, complemented by two 4–20 mA analogue outputs. The version with a Wi-Fi module enables wireless connection of a smartphone or tablet for configuration and calibration via a web interface, with no app installation required. In addition, the device includes four LEDs and an audible alarm, which immediately alert operators to an exceeded set limit directly at the installation site, without the need to monitor a remote control system. 

Typical applications

The E2639-C2H4 detector is intended for monitoring ethylene in environments such as fruit and vegetable storage facilities, ripening chambers, greenhouses, food processing plants, and other operations where ethylene is used as a ripening regulator or where it may be unintentionally generated as a product of biological processes. The device helps prevent health risks associated with exposure to this gas and contributes to ensuring the safety of both personnel and operations.

3D model

Ethylene (C2H4)

Ethylene is a colourless gas with a faintly sweet odour, which is practically imperceptible at very low concentrations without the use of a detector. Although it is not directly fatal during short-term exposure, at higher levels it displaces oxygen in the air and may cause dizziness, disorientation, or loss of consciousness. However, the principal hazard is its high flammability — even relatively low concentrations of ethylene in air can lead to explosion or fire in enclosed spaces, making it a gas that requires continuous monitoring.

Smart communication – ideal for fire alarm systems

The E2639 detector combines the advantages of an autonomous safety device and an intelligent communication node. It is designed for seamless integration with fire alarm systems (EPS) and offers a wide range of outputs for comprehensive control:

  • Autonomy: 3× volt-free SPDT relays for direct control of equipment or safe system shutdown.
  • Connectivity: Dual RS485 Modbus RTU interface for real-time digital export of measured data to a higher-level system (BMS).
  • Control: 2× 4–20 mA analogue outputs intended for precise control of the ventilation frequency inverter.
Detektor E2639

WiFi calibration from any smart device

Compared to the standard version, the E2639-WF has an integrated WiFi module that turns calibration and configuration into a matter of minutes – with no tools and without removing the cover. The access point is activated using a magnetic key, and the configuration interface opens in the browser of a phone or tablet, with no need to download any app. The interface is password-protected with separate access levels for end users and integrators, so everyone works only within their own part of the settings.

Factory settings:

  • Measurement range: 0...1500 ppm
  • ALARM1 (RE1): 375 ppm
  • ALARM2 (RE2): 750 ppm
  • ALARM3 (RE3): sensor fault
    • Automatic alarm reset after ventilation
  • Analogue outputs: 4-20mA = 0...1500 ppm
  • ModBus RTU address: Baud rate 9600, Parity None, Stop bits 1, Slave ID 1

Key features

  • Sensor type: Electrochemical sensor
  • Measurement range: 0...1500 ppm
  • Resolution: 1 ppm
  • T90 response time: approx. 60 s
  • Recommended recalibration interval: 6–12 months
  • Estimated sensor lifetime: > 2 years
  • 1-year warranty on the sensor itself (2 years on the entire device excluding the sensor)

Calibration certificate

Each detector package includes the original manufacturer's calibration certificate in English, confirming the accuracy and correctness of measurement at the time of leaving the factory.

We respond to your product queries as quickly as possible, usually within 24 hours.

Nenašli jste to, co jste chtěli vědět?