Questions? +32 460 226 991 (English). EU-wide delivery!

Smart Gas Detector for Refrigerant R134a with Wi-Fi Module EVIKON E2639-HFC(R134a)-WF, 230VAC

  • 2 variant

Smart Gas Detector for Refrigerant R134a with Wi-Fi Module EVIKON E2639-HFC(R134a)-WF, 230VAC

EVIKON
  • Product code: E2639-R134A-WF-230
  • Manufacturer code: E2639-HFC(R134a)-WF-230
  • Warranty: 2 years

Smart refrigerant detector (R134a) EVIKON E2639 with a range of 0...2500 ppm. Durable IP65-rated enclosure, 3 relays, RS485 Modbus communication, Wi-Fi module, built-in LED and audible alarm. More information

  • Availability

    Out of stock - can be requested

  • Out of stock  
Price excluding VAT € 440,00
Price with VAT 21 % € 532,40

Product variants

+

Parameters and catalogs

Detector type Stationary
Equipment Siren 85dB, LED
IP Rating IP 65
Output signal ModBus RS485, 3x SPDT relay, 2x Analogue output 4-20mA
Power Supply 230 VAC
Type of gas HFC Refrigerants - R134a
Weight 0.50 kg

Evikon E2639-HFC(R134a) is a detector designed for monitoring high concentrations of R134a refrigerant in the air. The device is equipped with a temperature-compensated sensor that ensures reliable detection and stable measurement, and it is housed in a wall-mounted enclosure with IP65 protection. The E2639 features three SPDT relays with a maximum load of 250 VAC 5 A. Two relays are used for so-called two-stage detection. The third relay indicates a sensor fault. Communication with higher-level systems is provided by the RS485 Modbus RTU digital interface, complemented by two 4–20 mA analogue outputs. The version with a Wi-Fi module allows wireless connection of a smartphone or tablet for configuration and calibration via a web interface – with no need to install an app. In addition, the device includes four LEDs and an audible alarm, which immediately alert operators to an exceeded set limit directly at the installation site – without the need to monitor a remote control system. 

Typical applications

The E2639-HFC detector is intended for monitoring R134a refrigerant leaks in environments such as plant rooms, air-conditioning and refrigeration equipment, refrigerant stores, or other installations where refrigerant concentrations need to be monitored. The device is used for early detection of refrigerant leaks, helping to minimise the risks associated with leakage and protect both the environment and the equipment.

Model molekuly

1,1,1,2-Tetrafluoroethane (R134a)

R134a is a synthetic refrigerant widely used in refrigeration and air-conditioning systems. It is a colourless gas with a faint odour and low toxicity. Although it is non-flammable, its leakage may impair air quality or contribute to greenhouse gas emissions. Monitoring R134a leaks is essential for maintaining equipment safety and complying with environmental standards.

Smart communication – ideal for fire alarm systems

The E2639 detector combines the benefits of an autonomous safety device and an intelligent communication node. It is designed for seamless integration with fire alarm systems (EPS) and offers a wide range of outputs for comprehensive control:

  • Autonomy: 3× volt-free SPDT relays for direct control of equipment or safe system shutdown.
  • Connectivity: Dual RS485 Modbus RTU interface for digital export of measured data in real time to a higher-level system (BMS).
  • Control: 2× 4–20 mA analogue outputs intended for precise control of the ventilation frequency inverter.
Detektor E2639

WiFi calibration from any smart device

Compared with the standard version, the E2639-WF has an integrated WiFi module that turns calibration and configuration into a matter of minutes – with no tools and without removing the cover. The access point is activated using a magnetic key, and the configuration interface opens in the browser of a phone or tablet, with no need to download any app. The interface is password-protected with separate access levels for end users and integrators, so everyone works only within their own part of the settings.

Factory settings:

  • Measuring range: 0...2500 ppm
  • ALARM1 (RE1): 1000 ppm
  • ALARM2 (RE2): 2000 ppm
  • ALARM3 (RE3): sensor fault
    • Automatic alarm reset after ventilation
  • Analogue outputs: 4-20 mA = 0...2500 ppm
  • ModBus RTU address: Baud rate 9600, Parity None, Stop bits 1, Slave ID 1

Key features

  • Sensor type: Semiconductor sensor
  • Measuring range: 0...2500 ppm
  • Resolution: 1 ppm
  • T90 response time: approx. 120 s
  • Recommended recalibration interval: 6–12 months
  • Estimated sensor lifetime: > 5 years
  • 1-year warranty on the sensor itself (2 years on the complete device excluding the sensor)

Calibration certificate

Each detector package includes the manufacturer’s original calibration certificate in English, confirming the accuracy and correctness of measurement at the time it leaves the factory.

We respond to your product queries as quickly as possible, usually within 24 hours.