Questions? +32 460 226 991 (English). EU-wide delivery!

Smart Gas Detector for Refrigerant R407c with Wi-Fi Module EVIKON E2639-HFC(R407c)-WF, 230VAC

  • 2 variant

Smart Gas Detector for Refrigerant R407c with Wi-Fi Module EVIKON E2639-HFC(R407c)-WF, 230VAC

EVIKON
  • Product code: E2639-R407C-WF-230
  • Manufacturer code: E2639-HFC(R407c)-WF-230
  • Warranty: 2 years

Smart refrigerant detector (R407c) EVIKON E2639 with a range of 0...2500 ppm. Durable IP65-rated enclosure, 3 relays, RS485 Modbus communication, Wi-Fi module, built-in LED and audible alarm. More information

  • Availability

    Out of stock - can be requested

  • Out of stock  
Price excluding VAT € 440,00
Price with VAT 21 % € 532,40

Product variants

+

Parameters and catalogs

Detector type Stationary
Equipment Siren 85dB, LED
IP Rating IP 65
Output signal ModBus RS485, 3x SPDT relay, 2x Analogue output 4-20mA
Power Supply 230 VAC
Type of gas HFC Refrigerants - R407C
Weight 0.50 kg

Evikon E2639-HFC(R407c) is a detector designed to monitor high concentrations of R407c refrigerant in the air. The device is equipped with a temperature-compensated sensor that ensures reliable detection and stable measurement, and it is housed in a wall-mounted enclosure with IP65 protection. The E2639 features three SPDT relays with a maximum load of 250 VAC 5 A. Two relays are used for so-called two-stage detection. The third relay indicates a sensor fault. Communication with higher-level systems is provided via the RS485 Modbus RTU digital interface, complemented by two 4–20 mA analogue outputs. The version with a Wi-Fi module enables wireless connection of a smartphone or tablet for configuration and calibration via a web interface – with no need to install an app. In addition, the device includes four LEDs and an audible alarm, which immediately alert operators to an exceeded set limit directly at the installation site – without the need to monitor a remote control system. 

Typical applications

The E2630-HFC detector is designed to monitor R407c refrigerant leaks in environments such as plant rooms, air-conditioning and refrigeration equipment, refrigerant stores, or other installations where refrigerant concentrations need to be monitored. The device is used for early leak detection, helping to minimise the risks associated with refrigerant leakage and protect both the environment and the equipment.

1,3,3,3-tetrafluoropropene (R407c)

R407c is a synthetic refrigerant commonly used in air-conditioning and refrigeration systems. It is a blend of three hydrofluorocarbon gases that provide efficient heat transfer. Although it is non-flammable, an R407c leak can contribute to greenhouse gas emissions and affect air quality. Monitoring R407c leaks is essential for ensuring equipment safety and protecting the environment.

Smart communication – ideal for fire alarm systems

The E2639 detector combines the benefits of an autonomous safety device and an intelligent communication node. It is designed for seamless integration with fire alarm systems (EPS) and offers a wide range of outputs for comprehensive control:

  • Autonomy: 3× volt-free SPDT relays for direct control of equipment or safe system shutdown.
  • Connectivity: Dual RS485 Modbus RTU interface for real-time digital export of measured data to a higher-level system (BMS).
  • Control: 2× 4–20 mA analogue outputs intended for precise control of the ventilation frequency inverter.
Detektor E2639

Wi-Fi calibration from any smart device

Compared to the standard version, the E2639-WF has an integrated Wi-Fi module that turns calibration and configuration into a matter of minutes – with no tools and without removing the cover. The access point is activated using a magnetic key, and the configuration interface opens in the browser of a phone or tablet, with no need to download any app. The interface is password-protected with separate access levels for end users and integrators, so everyone works only within their own section of the settings.

Factory settings:

  • Measuring range: 0...2500 ppm
  • ALARM1 (RE1): 1000 ppm
  • ALARM2 (RE2): 2000 ppm
  • ALARM3 (RE3): sensor fault
    • Automatic alarm reset after ventilation
  • Analogue outputs: 4-20 mA = 0...2500 ppm
  • Modbus RTU address: Baud rate 9600, Parity None, Stop bits 1, Slave ID 1

Key features

  • Sensor type: Semiconductor sensor
  • Measuring range: 0...2500 ppm
  • Resolution: 1 ppm
  • T90 response time: approx. 120 s
  • Recommended recalibration interval: 6–12 months
  • Estimated sensor lifetime: > 5 years
  • 1-year warranty on the sensor itself (2 years on the complete device excluding the sensor)

Calibration certificate

Each detector package includes the manufacturer’s original calibration certificate in English, confirming the accuracy and correctness of measurement at the time of manufacture.

We respond to your product queries as quickly as possible, usually within 24 hours.

Nenašli jste to, co jste chtěli vědět?